A reusable QCM biosensor with stable antifouling nano-coating for on-site reagent-free rapid detection of E. coli O157:H7 in food products

Logo poskytovatele
Logo poskytovatele

Varování

Publikace nespadá pod Fakultu sportovních studií, ale pod Přírodovědeckou fakultu. Oficiální stránka publikace je na webu muni.cz.
Autoři

FORINOVÁ Michala PILIPENCO Alina LYNN N. Scott OBOŘILOVÁ Radka ŠIMEČKOVÁ Hana VRABCOVÁ Markéta SPASOVOVÁ Monika JACK Rachael HORÁK Petr HOUSKA Milan SKLÁDAL Petr ŠEDIVÁK Petr FARKA Zdeněk VAISOCHEROVÁ-LÍSALOVÁ Hana

Rok publikování 2024
Druh Článek v odborném periodiku
Časopis / Zdroj Food Control
Fakulta / Pracoviště MU

Přírodovědecká fakulta

Citace
www https://www.sciencedirect.com/science/article/pii/S0956713524004122
Doi http://dx.doi.org/10.1016/j.foodcont.2024.110695
Klíčová slova Antifouling coating; E. coli O157:H7 detection; QCM biosensor; On-site analysis; Reusability
Přiložené soubory
Popis Numerous biosensors have shown exceptional analytical performance under laboratory conditions, yet only a few are capable of on-site use with complex, non-model samples while exhibiting reliable analytical performance. Here, we present a new portable biosensor for the rapid (30 min) and accurate detection of bacterial agents in “real-world” food samples, which are originally in either solid or liquid form. The biosensor combines well-established quartz crystal microbalance (QCM) technology, with innovative terpolymer brush nano-coatings on the sensing surface to efficiently reduce non-specific fouling from food samples. Following reagent-free sample preparation, where solid food samples are homogenized, we validated the sensor's detection capabilities on native pathogenic Escherichia coli O157:H7 (E. coli O157:H7) in hamburgers, Czech dumplings, and milk. We achieved limits of detection (LOD), as low as 7.5 × 10^2 CFU/mL in milk, a value approaching fundamental QCM limits, using a simple direct detection assay format. The biosensor's exceptional reusability was demonstrated through 60 sequential hamburger sample injections, resulting in only a minor LOD shift toward the end of series. A 10-min sonication treatment during sample preparation significantly enhanced sensitivity for E. coli O157:H7 in hamburgers and dumplings, yielding LODs as low as 3.1 × 10^3 CFU/mL and 2.6 × 10^4 CFU/mL, respectively. For on-site analysis, we integrated the nano-coated sensing chip into a custom-built four-channel portable QCM biosensor with an optimized microfluidic system, which can be produced on a scale suitable for practical deployment.
Související projekty:

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.

Další info