Bronchoalveolar lavage fluid and serum 1,3-beta-d-glucan testing for invasive pulmonary aspergillosis diagnosis in hematological patients: the role of factors affecting assay performance

Varování

Publikace nespadá pod Fakultu sportovních studií, ale pod Lékařskou fakultu. Oficiální stránka publikace je na webu muni.cz.
Autoři

WEINBERGEROVÁ Barbora KABUT Tomáš KOCMANOVÁ Iva LENGEROVÁ Martina POSPÍŠIL Zdeněk KRÁL Zdeněk MAYER Jiří

Rok publikování 2020
Druh Článek v odborném periodiku
Časopis / Zdroj Scientific Reports
Fakulta / Pracoviště MU

Lékařská fakulta

Citace
www https://www.nature.com/articles/s41598-020-75132-3
Doi http://dx.doi.org/10.1038/s41598-020-75132-3
Klíčová slova beta-D-glucan; bronchoalveolar lavage fluid; serum; invasive pulmonary aspergillosis; hematological malignancy
Přiložené soubory
Popis Invasive fungal disease (IFD) early diagnosis improves hematological patient survival. Non-culture-based methods may reduce diagnostic time to identify IFD. As complex data on the value of 1,3-beta -d-glucan (BDG) from bronchoalveolar lavage fluid (BALF) compared to serum for the most frequent invasive pulmonary aspergillosis (IPA) diagnosis are scarce, particularly including evaluation of potential factors adversely affecting BDG assay, we provided prospective single-center analysis evaluating 172 episodes of pulmonary infiltrates with BDG detection in BALF and serum samples collected in parallel among hematological patients from 2006 to 2015. Proven and probable IPA were documented in 13.4% of the episodes. Sensitivity (SEN), specificity (SPE), positive and negative predictive value (PPV; NPV), and diagnostic odds ratio (DOR) of the BDG assay using standard (80 pg/ml) cut-off for BALF were: 56.5%; 83.2%; 34.2%; 92.5%, and 6.5, respectively, and for serum were: 56.5%; 82.6%; 33.3%; 92.5%, and 6.2, respectively. The same BDG assay parameters employing a calculated optimal cut-off for BALF (39 pg/ml) were: 78.3%; 72.5%; 30.5%; 95.6%, and 9.5, respectively; and for serum (40 pg/ml) were: 73.9%; 69.1%; 27.0%; 94.5%, and 6.3, respectively. While identifying acceptable SEN, SPE, and DOR, yet low PPV of both BALF and serum BDG assay for IPA diagnosis, neither the combination of both materials nor the new optimal BDG cut-off led to significant test quality improvement. Absolute neutrophil count and aspirated BALF volume with a significant trend affected BDG assay performance. The BDG test did not outperform galactomannan assay.
Související projekty:

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.

Další info