The variability of standard artificial soils: cadmium and phenanthrene sorption measured by a batch equilibrium method

Logo poskytovatele

Varování

Publikace nespadá pod Fakultu sportovních studií, ale pod Přírodovědeckou fakultu. Oficiální stránka publikace je na webu muni.cz.
Autoři

BIELSKÁ Lucie HOVORKOVÁ Ivana KUTA Jan MACHÁT Jiří HOFMAN Jakub

Rok publikování 2017
Druh Článek v odborném periodiku
Časopis / Zdroj Ecotoxicology and Environmental Safety
Fakulta / Pracoviště MU

Přírodovědecká fakulta

Citace
www http://www.sciencedirect.com/science/article/pii/S014765131630361X
Doi http://dx.doi.org/10.1016/j.ecoenv.2016.09.015
Obor Vliv životního prostředí na zdraví
Klíčová slova Artificial soil; Sorption; Cadmium; Phenanthrene; Soil variability; Batch equilibrium method
Popis Artificial soil (AS) is used in soil ecotoxicology as a test medium or reference matrix. AS is prepared according to standard OECD/ISO protocols and components of local sources are usually used by laboratories. This may result in significant inter-laboratory variations in AS properties and, consequently, in the fate and bioavailability of tested chemicals. In order to reveal the extent and sources of variations, the batch equilibrium method was applied to measure the sorption of 2 model compounds (phenanthrene and cadmium) to 21 artificial soils from different laboratories. The distribution coefficients (K-d) of phenanthrene and cadmium varied over one order of magnitude: from 5.3 to 61.5 L/kg for phenanthrene and from 17.9 to 190 L/kg for cadmium. Variations in phenanthrene sorption could not be reliably explained by measured soil properties; not even by the total organic carbon (TOC) content which was expected. Cadmium logK(d) values significantly correlated with cation exchange capacity (CEC), pH(H2O) and pH(KCl), with Pearson correlation coefficients of 0.62, 0.80, and 0.79, respectively. CEC and pH(H2O) together were able to explain 72% of cadmium logKd variability in the following model: logK(d) =0.29 pH(H2O)+0.0032 CEC -0.53. Similarly, 66% of cadmium logKd variability could be explained by CEC and pH(KCl) in the model: logKd =0.27 pH(KCl) + 0.0028 CEC -0.23. Variable cadmium sorption in differing ASs could be partially treated with these models. However, considering the unpredictable variability of phenanthrene sorption, a more reliable solution for reducing the variability of ASs from different laboratories would be better harmonization of AS preparation and composition.
Související projekty:

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.

Další info