Alternative method for flow measurement of clog producing gases and liquids in PVD and PECVD processes
Authors | |
---|---|
Year of publication | 2011 |
Type | Article in Proceedings |
Conference | Book of Extended Abstracts POTENTIAL AND APPLICATIONS OF THIN CERAMIC AND METAL COATINGS 2011 |
MU Faculty or unit | |
Citation | |
Field | Plasma physics |
Keywords | flow measurement; PECVD; Prandtl-Pitot tube; Iron pentacarbonyl |
Description | In this work we present a method to measure gas flow where conventional mass flow-meters cannot be used. These are the cases when one operates with highly reactive gases, unstable substances or meets other difficulties. We successfully used Prandtl-Pitot tube for measurement of iron pentacarbonyl flow during the process of plasma synthesis of nanoparticles. |
Related projects: |