In-line Bragg magnifier based on V-shaped germanium crystals

Warning

This publication doesn't include Faculty of Sports Studies. It includes Faculty of Science. Official publication website can be found on muni.cz.
Authors

VAGOVIČ P. KORYTÁR D. MIKULÍK Petr CECILIA A. FERRARI C. YANG Y. HANSCHKE D. HAMANN E. PELLICCIA D. LAFFORD T.A. FIEDERLE M. BAUMBACH T.

Year of publication 2011
Type Article in Periodical
Magazine / Source Journal of Synchrotron Radiation
MU Faculty or unit

Faculty of Science

Citation
Web http://scripts.iucr.org/cgi-bin/paper?mo5017
Doi http://dx.doi.org/10.1107/S090904951102989X
Field Solid matter physics and magnetism
Keywords x-ray optics; x-ray diffraction; monochromators
Description In this work an X-ray imaging system based on a recently developed in-line two-dimensional Bragg magnifier composed of two monolithic V-shaped crystals made of dislocation-free germanium is presented. The channel-cut crystals were used in one-dimensional and in two-dimensional (crossed) configurations in imaging applications and allowed measurement of phase-contrast radiograms both in the edge-enhanced and in the holographic regimes. The measurement of the phase gradient in two orthogonal directions is demonstrated. The effective pixel size attained was 0.17 um in the one-dimensional configuration and 0.5 um in the two-dimensional setting, offering a twofold improvement in spatial resolution over devices based on silicon. These results show the potential for applying Bragg magnifiers to imaging soft matter at high resolution with reduced dose owing to the higher efficiency of Ge compared with Si.
Related projects:

You are running an old browser version. We recommend updating your browser to its latest version.

More info