Measurement of plasma potential waveform in capacitive discharge

Investor logo

Warning

This publication doesn't include Faculty of Sports Studies. It includes Faculty of Science. Official publication website can be found on muni.cz.
Authors

DVOŘÁK Pavel

Year of publication 2009
Type Conference abstract
MU Faculty or unit

Faculty of Science

Citation
Description The uncompensated probe was used for measurement of plasma potential waveforms. A method is presented that enables calculation of probe sheath voltage and, consequently, enables to get the plasma potential waveform by means of probe measurements. The method was successfully tested in nitrogen plasma. In order to get reliable results the method requires knowledge of plasma parameters which can be measured by a compensated Langmuir probe. It was shown that the waveforms of plasma potential and probe voltage differ significantly. Therefore, the influence of the probe sheath voltage whose calculation is presented can not be neglected by measurement of the plasma potential. At low pressure, the plasma potential waveform contained high amount of higher harmonic frequencies that were ignited namely during the fast expansion of the sheath at the powered electrode.
Related projects: