Když selžou dvě chlopně, přichází na řadu třetí (transkatétrová implantace chlopeň do chlopně)

Warning

This publication doesn't include Faculty of Sports Studies. It includes Faculty of Medicine. Official publication website can be found on muni.cz.
Title in English When two valves fail, it’s time for a third one (transcatheter valve-in-valve implantation)
Authors

KOMOROVÁ Zuzana SITAR Jan SEMÉNKA Jiří GROCH Ladislav ŠPINAROVÁ Lenka ĎURČANSKÁ Karin

Year of publication 2023
Type Article in Periodical
Magazine / Source Intervenční a akutní kardiologie
MU Faculty or unit

Faculty of Medicine

Citation
Web https://www.solen.cz/artkey/kar-202303-0003_kdyz_selzou_dve_chlopne_prichazi_na_radu_treti_transkatetrova_implantace_chlopen_do_chlopne.php
Doi http://dx.doi.org/10.36290/kar.2023.015
Keywords aortic stenosis; transcatheter aortic valve implantation; echocardiography
Description This case report depicts a 90-year-old patient with exertional dyspnea of NYHA class III following bioprosthetic replacement of the aortic valve (Sorin Perceval S sutureless). She developed a relatively early (6 years), highly significant (AVA 0.3 cm2) and symptomatic degeneration of bioprosthesis with severe left ventricular depression and a left ventricular ejection fraction of 25%. At a heart center, the patient underwent a valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) procedure using the 23-mm CoreValve Evolut R valve, resulting in an early optimal tonometric, angiographic, echocardiographic and clinical effect. The surgery and the course of hospitalization were without major complications. A favorable clinical outcome persists even at 18 months of follow-up.
Related projects: