Influence of compression aids on baroreflex in patients after cervical spinal cord injury

Warning

This publication doesn't include Faculty of Sports Studies. It includes Faculty of Medicine. Official publication website can be found on muni.cz.
Authors

SVAČINOVÁ Jana ONDRUŠOVÁ Katarína JAVORKA Michal NOVÁKOVÁ Zuzana NOVÁKOVÁ Marie

Year of publication 2018
Type Article in Proceedings
Conference Noninvasive methods in cardiology 2018
MU Faculty or unit

Faculty of Medicine

Citation
Web http://www.med.muni.cz/dokumenty/pdf/noninvasive_methods_in_cardiology_2018.pdf
Keywords Cervical spinal cord injury; orthostatic hypotension; baroreflex; compression aids
Description Introduction: Patients after cervical spinal cord injury (cSCI) often suffer from orthostatic hypotension (OH). Although vagal cardiac chronotropic effect is preserved in cSCI, baroreflex vascular tone regulation is impaired due to interrupted sympathetic pathways below the cSCI level. Patients usually use compression aids (CA, e.g. stockings, abdominal corset) to mitigate blood pressure (BP) drop during orthostasis. This study aimed to assess the influence of CA on baroreflex function in cSCI patients during orthostasis. Methods: BP was continuously recorded in 9 cSCI patients during passive orthostasis without and with CA. Beat-to-beat systolic blood pressure (SBP) and inter-beat intervals (IBI) sequences were obtained from continuous non-invasive BP recording. Pulse pressure (PP) was evaluated as a mean of beat-to-beat differences between SBP and diastolic pressures. Closed loop of SBP IBI interaction was mathematically opened by bivariate autoregressive model; causal coherence (a measure of IBI and SBP synchronization) and gain estimating baroreflex sensitivity (BRS) were calculated in baroreflex direction (from SBP to IBI). Results: When CA were applied, coherence and PP were significantly increased as compared to orthostasis without CA (p < 0.05). CA application was also associated with an increase of BRS (borderline significant; p = 0.059). Patients reported less OH symptoms when wearing CA. Conclusion: Use of CA increased venous return and consequently stroke volume expressed as an increase of PP in this study. This probably prevented the baroreflex sensitivity decrease during orthostasis. We suppose that positive influence of CA on blood pressure regulation during orthostasis weakened OH symptoms in cSCI.
Related projects:

You are running an old browser version. We recommend updating your browser to its latest version.

More info