Treatment of early localised infection of the Omniflow® II prosthesis with negative pressure wound therapy

Warning

This publication doesn't include Faculty of Sports Studies. It includes Faculty of Medicine. Official publication website can be found on muni.cz.
Authors

KREJČÍ Miroslav STAFFA Robert GLADIŠ P.

Year of publication 2016
Type Article in Periodical
Magazine / Source Wound Practice and Research
MU Faculty or unit

Faculty of Medicine

Citation
Field Surgery incl. transplantology
Keywords Omniflow® II prosthesis; infection; wound therapy
Description A biosynthetic vascular prosthesis is a special type of vascular graft. Implantation of this type of prosthesis can be considered for patients with limb ischaemia, diabetes mellitus, insufficient saphenous vein, and trophic ulcers. We present a rare case of successful healing of an early Szilagyi grade III vascular prosthetic infection in the groin using a topical negative pressure device and moist wound healing materials.