Ferrocene-Boronic Acid–Fructose Binding Based on Dual- Plate Generator–Collector Voltammetry and Square-Wave Voltammetry

Investor logo

Warning

This publication doesn't include Faculty of Sports Studies. It includes Central European Institute of Technology. Official publication website can be found on muni.cz.
Authors

LI Meng XU Su-Ying GROSS Andrew J. HAMMOND Jules L. ESTRELA Pedro WEBER James LACINA Karel JAMES Tony D. MARKEN Frank

Year of publication 2015
Type Article in Periodical
Magazine / Source ChemElectroChem
MU Faculty or unit

Central European Institute of Technology

Citation
Web http://onlinelibrary.wiley.com/doi/10.1002/celc.201500016/full
Doi http://dx.doi.org/10.1002/celc.201500016
Field Electrochemistry
Keywords boronic acids; electroanalysis; ferrocene; saccharides; voltammetry
Description The interaction of ferrocene-boronic acid with fructose is investigated in aqueous 0.1 M phosphate buffer at pH 7, 8 and 9. Two voltammetric methods, based on 1) a dual-plate generator–collector micro-trench electrode (steady state) and 2) a square-wave voltammetry (transient) method, are applied and compared in terms of mechanistic resolution. A combination of experimental data is employed to obtain new insights into the binding rates and the cumulative binding constants for both the reduced ferrocene-boronic acid (pH dependent and weakly binding) and for the oxidised ferrocene-boronic acid (pH independent and strongly binding).