Cathode voltage and discharge current oscillations and spoke behavior during HiPIMS discharge

Investor logo
Investor logo
Investor logo

Warning

This publication doesn't include Faculty of Sports Studies. It includes Faculty of Science. Official publication website can be found on muni.cz.
Authors

KLEIN Peter HNILICA Jaroslav VAŠINA Petr HUBIČKA Zdeněk ČADA Martin

Year of publication 2015
Type Appeared in Conference without Proceedings
MU Faculty or unit

Faculty of Science

Citation
Description The spokes presence and their behavior were studied by high-speed imaging. The spoke appearance was strongly dependent on the pressure. At very low pressure, the triangular spoke shape was well recognized but with increasing pressure the shape became diffusive. Overreaching 2 Pa there was no spokes recognizable. Camera enables to record two successive images from the same pulse with time delay of 3 µs.Spoke rotation velocity and frequency was derived from the spoke image shift in the pressure range 0.18-0.5 Pa, where the spokes were well distinguished. The spoke characteristic frequency was arbitrary determined as multiplication of number of spokes with rotation frequency and ranges from 77 to 178 kHz. Spoke characteristic frequency is in the same order of magnitude as observed oscillations on cathode voltage and discharge current, nevertheless they are not identical. Spoke characteristic frequency is 3-4 times lower than the frequency of the oscillations.
Related projects:

You are running an old browser version. We recommend updating your browser to its latest version.